8500 Poet IQ Anesthetic Gas Monitor 8500 Poet IQ
— Anesthetic Gas monitor featuring NDIR technology identifiesand measures five anesthetic agent gases: Halothane, Isoflurane, Enflurane, Sevoflurane, and Desflurane. And Breath-by-breath O2, CO, and N2O monitoring.Gas flow sampled at 100 ml/min to 200 ml/min. Fast warm-up time ensures full accuracy within minutes.


Technical Specifications


Gas Monitoring
Method: Sidestream; Non-dispersive infrared (NDIR)
Identified Gases: Halothane, Isoflurane, Enflurane, Desflurane, Sevoflurane, CO2, N2O, Oxygen
Output Data:


Inspired and end-tidal gas concentrations; continuous real-time gas concentrations; respiratory rate (elapsed time since last breath); agent identification (primary agent and mixed agents); system information (diagnostic status messages)


Agent Detection
Measurement Range:
Halothane: 0 to 10%
Isoflurane: 0 to 10%
Enflurane: 0 to 10%
Desflurane: 0 to 20%
Sevoflurane: 0 to 10%
CO2: 0 to 12.5%
N2O: 0 to 99%
Oxygen: (Optional) 0 to 100%


Measurement Accuracy:
Agents: กำ (0.1% abs. + 4% reading)
CO2: กำ 0.2% abs. or 4% of reading
N2O: กำ (1.5% abs. + 4% of reading)
Oxygen: กำ 0.3 vol.% (for 0-90%), กำ 0.4 vol.% (for 91-99%)
Time to Detect Agent: < 15 seconds @ 200 ml/min
Agent Detection Resolution: 0.1 Volume Percent
Mixed Gas Threshold: 0.2 vol. % +10% of total concentrations


Rise Time:
Agents: 450 msec
CO2: 350 msec
N2O: 400 msec
Oxygen: 600 msec


Response Time:
Agents: 2.50 seconds
CO2: 2.25 seconds
NO: 2.50 seconds
Oxygen 1.50 seconds
Warm-up Time: 1 minute to first waveforms; < 20 minutes to full accuracy


Respiration Rate
Range: 1 to 120 breaths/minute
Accuracy: กำ 2 bpm or 2% of reading


System Features
System Configuration:

Modular design with by-directional communication, via cable, to the Poet Plus 8100 vital signs monitor.


Waveform Output:

Halothane, Isoflurane, Enflurane, Desflurane, Sevoflurane, CO2, N2O, O2
Concentration Units: Vol.%, Torr, kPa, mmHg
Flow Rates: 100 ml/min, 150 ml/min, 200 ml/min
Occlusion Clearing:
Automatic
Auto Zeroing: Occurs 30 to 60 minutes
Duration: 3.0 to 7.0 seconds
Manual user calibration not required.
Temperature stabilized optical assembly


Alarm Characteristics:
EN 475, Adjustable; with audible and visual indications from the vital signs monitor.
Alarm Levels: High, Medium, Low, Informational

Alarm Modes: Adult/Pediatric/Neonate
High and low limit settings for each mode.

Trends:
24 hours of stored data in vital signs monitor with graphical and tabular trends.


Power Requirements
10 to 28 VDC: 9 watts warm-up, 6 watts operational
Receives power from vital signs monitor.


Mechanical
Weight: 6.5 lbs (2.95 kg)
Size: 3.8¨ (H) x 10.4¨ (W) x 8.2¨ (D); 9.65 cm (H) x 26.4 cm (W) x 20.8 cm (D)


Environmental
Operating Temperature: 15° to 35° C; 59o° to 95° F
Storage Temperature: -5° to 50° C; 23° to 122° F
Operating/Storage Humidity: 15% to 95%, noncondensing
Altitude: -1,000 to 10,000 ft. (-300m to 3000m)
Type of Protection: Class I Equipment
Degree of Protection: Type CF, Defibrillator-proof
Protection against ingress: Ordinary

Quality systems registered to ISO 9001 and CE marking per Annex II, Clause 3 of Council Directive No. 93/42/EEC concerning medical devices by TUV Product Service GmbH, Munich.

Specifications subject to change without notice.