507VVHS VitalView Central Station 507VVHS VitalView
 — Communicates with bedside monitors and patient-borne multiple parameter devices for continuous, comprehensive vital signs monitoring. Advanced 2.4 GHz digital spread spectrum technology and optional integrated RemoteView™ Paging System provide maximum clinical and installation flexibility.

Technical Specifications

Central Station
Display
Screen: 17" color CRT SVGA; optional 15" or 18" color flat panel LCD
Resolution: 1,024 x 768 Configuration: 16 independent ECG traces
Patients Displayed: 8
Modes: 8 patients or single patient detailed view

Mechanical
Display
Size (excluding base):
17" color CRT SVGA: 18" (H) x 17" (W) x 16" (D); 45.7cm (H) x 43.2cm (W) x 40.64cm (D)
15" color flat panel LCD: 11.4" (H) x 15.25" (W) x 3.064" (D); 29cm (H) x 38.7cm (W) x 7.8cm (D)
18" color flat panel LCD: 15.57" (H) x 18.3" (W) x 3.86" (D); 39.5cm (H) x 46.5cm (W) x 9.8cm (D)
Weight (excluding base): 17": 36.4 lb; 16.2kg; 15": 15.51lb; 7.1kg; 18": 20.7 lb; 9.4kg

Computer Chassis
Size: 7" (H) x 17" (W) x 16" (D); 18cm (H) x 43cm (W) x 41cm (D)
Weight: 26 lb; 12kg
Electrical Requirements: 115/230 V; 50/60 Hz

User Interface
Description: Touchscreen, mouse, and/or keyboard

Environmental
Operating Temperature: 41¢X to 113¢X F; 5¢X to 45¢X C
Operating Humidity: 80% at 113¢X F (45¢X C), noncondensing, maximum
Storage Temperature: -4¢X to 113¢X F; -20¢X to 45¢X C
Storage Humidity: 95% at 113¢X F (45¢X C), noncondensing, maximum

Telemetry
RF
Transceiver: 2.4 GHz; ISM Band; via access points
Modulation: Frequency Hopping Spread Spectrum (FHSS)
Data Throughput: 1 Mb/sec

Alarms
Description: User-configurable for all monitored parameters
ECG: Asystole; Priority ECG Alert; ECG Alert; Alert
Limit: High/Low HR, NIBP, SpO2
Lead Disconnect: Fault RA, LA, LL, and V

Trend/Event Storage
Storage Capacity: 24-hr graphic and tabular trends of all parameters; 100 events
Event Storage Duration: 36 sec/event
Type: Internal 50mm thermal array recorder
Print Duration: Configurable

Pager
Description: Optional integral pager provides caregiver with remote notification of patient events and text messages.

Approved by ETL, CSA, CE, FCC. Quality systems registered to ISO 9001 and CE marking per Annex II, Clause 3 of Council Directive No. 93/42/EEC concerning medical devices by TUV Product Service GmbH, Munich.