506DXN2 Vital Signs Monitor 506DXN2 Vital Signs Monitor
506DXN2 Series Vital Signs Monitor - Vital signs monitor featuring Digital Oximetry and NIBP.
Optional IVACR predictive temperature also available.


Custom Configurations:
506DXN2: SpO2 and NIBP
506DXNP2: SpO2, NIBP and printer
506DXNT2: SpO2, NIBP, and predictive temperature
506DXNTP2: SpO2, NIBP, predictive temperature, and printer

Technical Specifications


Non-Invasive Blood Pressure
Technique: Oscillometric measure upon inflation
Measurement Time: <40 sec typical; 0 to 300mmHg; standard adult cuff
Automatic Measurement Cycles: 1, 2, 3, 5, 10, 15, 30, 45, 60 min; 2, 4 hr; STAT
Inflation Pressure Range: 0 to 300mmHg (Adult); 0 to 150mmHg (Neonate)
Resolution: 1mmHg
Accuracy: ¡Ó2mmHg or ¡Ó2% of reading, whichever is greater, over full range
STAT mode: 5 min of consecutive readings


Pulse Oximetry
Range: 1% to 99%
Resolution: 1%
Accuracy: 70% to 99% range: ¡Ó2%; 40% to 69% range: ¡Ó3%; <40%: unspecified
Method: Dual wavelength LED
Audio: Tone with each detected pulse; pitch varies with saturation


Heart (Pulse) Rate
Range: 20 to 300bpm
Accuracy: Greater of ¡Ó1bpm or ¡Ó1%, of reading unspecified for <30 or > 240 bpm
Update Time: Every sec
Resolution: 1bpm
Pulse Volume: 10 levels or Off


Temperature
Type: IVACR
Method: Predictive
Channels: 1
Range: Monitor mode: 80.0° to 108.0° F; 26.7° to 42.2° C
Accuracy: ¡Ó0.2° F (¡Ó0.1° C); tested in calibrated water bath
Resolution: 0.1° F or 0.1° C
Probe/Cable: Oral: Cat. No. 444; rectal (optional): Cat. No. 445


Alarms
Indication: Audible; visual
Volume: 10 levels or Off
Silence: Yes; 2 min or permanent
Parameter/Range/Default:
High Saturation: 70% to 98% or Off; Off
Low Saturation: 1% to 99% or Off; 90%
High Pulse Rate: 80 to 250bpm or Off; 150bpm
Low Pulse Rate: 20 to 150bpm or Off; 50bpm
High Systolic: 75 to 240mmHg or Off; 200mmHg
Low Systolic: 50 to 150mmHg or Off; 50mmHg
High Diastolic: 50 to 180mmHg or Off; 100mmHg
Low Diastolic: 15 to 50mmHg or Off; 30mmHg
High Mean: 70 to 200mmHg or Off; 150mmHg
Low Mean: 25 to 125mmHg or Off; 50mmHg
High Temperature: 80.6° to 107.6° F (27° to 42° C) or Off; 100° F (37.8°oC)
Low Temperature: 80.6° to 107.6° F (27° to 42° C) or Off; 94° F (34.4° C)

Trend Memory
Memory: ¡@¡@ ¡@Last 24 hrs and 250 readings: SpO2, pulse rate, NIBP, temperature

Displays
Type: LED
Parameters: NIBP, SpO2; temperature, pulse rate; pulse bar
Status: Alarm Silence; Sensor; Low Battery; External Power; Neonatal Mode
Text: Alphanumeric LCD
Languages: Selectable; English, French, German, Italian, Portuguese, Spanish.


System Output
Com Port: RS 232-compatible; digital or analog; mini-din


Printer
Type: Thermal array
Tabular Mode: 1, 2, 5, 10, 15, 30, 60 min intervals; 2, 4, 8, 12, 24 hr intervals; Auto BP; Off


Mechanical

Weight: Base unit with battery: 4.4 lb; 2kg
Size: Base unit: 6.5" (H) x 7" (W) x 6.125" (D); 16.5cm (H) x 17.8cm (W) x 15.5cm (D)
¡@¡@¡@
Power Requirements
Voltage: 60 Hz: 110/120 VAC; 50 Hz: 220/240 VAC
Battery: Sealed lead acid; life: 6.5 hr with NIBP every 15 min; recharge time: 6 hr


Environmental
Operating Temperature: 32° to 113° F; 0° to 45° C
Storage Temperature: 23° to 122° F; -5° to 50° C
Operating Humidity: 15% to 90%, noncondensing


Classification
Type of Protection: Class II equipment
Degree of Protection: Type CF defibrillator-proof equipment

Approved by UL, CSA, CE.

Quality systems registered to ISO 9001 and CE marking per Annex II, Clause 3 of Council Directive No. 93/42/EEC concerning medical devices by TUV Product Service GmbH, Munich.

Specifications subject to change without notice.
.